8.23 Signals A1 and A2
When using the V820/V850 control panel, direct access by means of the function key (key 9) is possible!
Function with control panel Parameter
Signal A1 and/or A2 On/Off with slide-in strip 1...4 (-F-) 008 = 5
(left-hand arrow = A1, right-hand arrow = A2)
Function with control panel V820/V850
Signal A1 On left-hand arrow above key On Key 8
Signal A2 On right-hand arrow above key On
Signals A1 and A2 On both arrows above key On
Signals A1 and A2 Off both arrows above key Off
Parameters 300-309, 330, 331 for A1 and 310-319, 335, 336 for A2 determine when and how long the signals are enabled
or disabled, or other conditions take effect.
When a V820 control panel is used, signals A1/A2 can be assigned to a seam using key 8 (slide-in strips 6, 8, 9 and 10).
Using parameter 300/310, it is possible to set which output (M1-M11 or VR) can be switched by A1/A2.
Using parameter 301/311, it is possible to select if signal A1/A2 is effective until the seam end, stop at the seam end, over
time or during stitch counting.
301/311 0 until seam end (parameter 320)
1 over time (parameter 304/305/314/315)
2 until stop at the seam end
3 during stitch counting (parameter 308/309/318/319)
4 puller function
Using parameter 302/312, it is possible to select if the signal A1/A2 shall be effective at the start of the seam, after light
barrier sensing or at the seam end.
302/312 0 Signal at the beginning of the seam
1 Signal after light barrier sensing
2 Signal at stop of the drive at the seam end
3 Signal from light barrier covered at the start of the seam
4 Signal only manually switchable
Using parameter 303/313, it is possible to select if the signals shall be activated with or without delay.
303/313 0 without delay time
1 after a delay time (parameter 308/318)
2 after a stitch count (parameter 309/319)
The delay time can be selected using parameter 304/314.
The ON period can be selected using parameter 305/315.
The speed mode can be set using parameter 306/316. The speed limitation is effective only when the signal is On.
306/316 0 Pedal controlled speed
1 Limitation to speed n9 (parameter 288)
2 Limitation to speed n11 (parameter 289)
The function for A1/A2 can be enabled or disabled separately using parameter 307/317.
Using parameter 308/318, it is possible to select if the signals shall be activated with or without delay stitch count.
308/318 0 without delay stitches
1 with delay stitches
Separate stitch counts can be selected using parameter 309/319.
The switch-off moment can be set using parameter 320.
320 0 signals effective until seam end
1 signals effective until pedal has been pressed to pos. 0 (neutral)
Using parameter 330 for signal A1 and parameter 335 for signal A2, it is possible to select if these signals and sewing foot
lifting shall be coupled or these signals and backtacking shall be coupled.
330/335 0 coupling off
1 coupling with sewing foot lifting
2 coupling with backtacking
3 coupling with sewing foot lifting and backtacking
Signals A1/A2 can be inverted using parameter 331/336.
Signals A1/A2 can be switched using the “F“ key on the V820 control panel if parameter 008 is set accordingly.