8 Functions with or without Control Panel
8.1 Softstart
Function with or without control panel Parameter
Softstart On/Off (SSt) 134
Softstart On/Off (with function key when using V820/V850) (-F-) 008 = 1
Softstart speed (n6) 115
Number of softstart stitches (SSc) 100
The letter symbols in parenthesis ( ) are visible only if a V820/V850 control panel is connected.
Functions:
after power on
at the beginning of a new seam
speed pedal controlled and limited to (n6)
lower speed of a parallel function prevailing (e. g. start backtack, stitch counting)
stitch counting synchronized to position 1
suspension with pedal in position 0 (neutral)
interruption by full heelback (position -2)
When using the V820/V850 control panel, direct access by means of the function key (key 9) is possible!
8.2 Sewing Foot Lifting
Function without control panel Key on control
Automatic in the seam Segment 5 On Key – (S4)
Automatic after thread trimming Segment 6 On
Function with control panel V810 V820
Automatic in the seam left-hand arrow above key On Key 3 Key 6
Automatic after thread trimming right-hand arrow above key On Key 3 Key 6
Function with or without control panel Parameter
Automatic sewing foot with pedal forward at the seam end if light barrier or (AFL) 023
stitch counting is On
Switch-on delay with pedal in position –1 (half heelback) (t2) 201
Start delay after switching off the sewing foot lift signal (t3) 202
Time of full power (t4) 203
Duty ratio (ED) with pulsing (t5) 204
Delay after thread wiping until sewing foot lifting (t7) 206
Fast disabling of sewing foot lift On/Off (FLS) 216
Time monitoring of sewing foot lift (tFL) 297
Upper limit ON period of sewing foot lifting 1...100 (EF-) 298
Sewing foot is lifted:
in the seam by half heelback (position -1)
or automatically (using key S4 on the control, segment 5 lights up)
or automatically (using key 3 on the V810 control panel)
or automatically (using key 6 on the V820/V850 control panel)
by pressing the key for manual sewing foot lift
after thread trimming by heelback (position -1 or -2)
or automatically (using key S4 on the control, segment 6 lights up)
or automatically (using key 3 on the V810 control panel)
or automatically (using key 6 on the V820/V850 control panel)
by pressing the key for manual sewing foot lift
automatically using the light barrier with pedal forward according to the setting
of parameter 023
automatically by stitch counting with pedal forward according to the setting of
parameter 023
switch-on delay after thread wiper (t7)